Siemens has published a security advisory covering two critical vulnerabilities in the RUGGEDCOM APE1808 industrial appliance when paired with Palo Alto Networks PAN-OS software. The flaws, identified as CVE-2026-109618 and CVE-2026-109619, originate from PHP memory management issues that can be triggered by multiple out-of-memory strategies, ultimately enabling remote code execution.
The first vulnerability, CVE-2026-109618, carries a CVSS v3.1 base score of 9.8 (CRITICAL). It occurs because PHP uses longjmp() for out-of-memory errors without properly initializing request memory in certain contexts. Subsequent cleanup routines may read or branch on uninitialized memory, leading to RCE. The second issue, CVE-2026-109619, scores 8.1 (HIGH) and involves global state that temporarily references request memory; failure to reset this state correctly can leave dangling pointers after memory is freed.
Affected products include RUGGEDCOM APE1808 running PAN-OS versions 10.2 All, 11.1 All, 11.2 All, 12.1 All, and 12.2 All. Both vulnerabilities are listed as known_affected. Siemens advises customers to upgrade to corresponding patched PAN-OS releases and contact support for additional remediation details.
Recommended Mitigations
- Apply vendor fixes by upgrading to the latest available PAN-OS version.
- Protect network access to devices using appropriate segmentation and firewalls.
- Follow Siemens operational guidelines for Industrial Security.
- Minimize internet exposure of control system devices and place them behind isolating firewalls.
- Use VPNs for remote access while ensuring they remain updated.
The advisory was originally issued by Siemens ProductCERT and later republished by CISA as ICSA-26-316-05. It affects critical manufacturing sectors worldwide, with the vendor headquartered in Germany.