Siemens Warns of Critical RUGGEDCOM APE1808 Vulnerabilities Tied to PAN-OS PHP Flaws

Siemens has released an advisory detailing two high-severity vulnerabilities affecting the RUGGEDCOM APE1808 industrial device when running Palo Alto Networks PAN-OS software. The flaws, tracked as CVE-2026-109618 and CVE-2026-109619, both stem from Use After Free conditions in PHP handling of out-of-memory errors and global state management. Exploitation can lead to remote code execution with CVSS scores of 9.8 and 8.1 respectively. The issues impact all versions of PAN-OS from 10.2 through 12.2 when deployed on the RUGGEDCOM APE1808 platform. Siemens recommends upgrading to patched PAN-OS releases and implementing network segmentation as immediate defensive measures. CISA has republished the advisory to increase visibility across critical infrastructure sectors worldwide.

CISA AlertsTranslated from English

Read at source

Siemens has published a security advisory covering two critical vulnerabilities in the RUGGEDCOM APE1808 industrial appliance when paired with Palo Alto Networks PAN-OS software. The flaws, identified as CVE-2026-109618 and CVE-2026-109619, originate from PHP memory management issues that can be triggered by multiple out-of-memory strategies, ultimately enabling remote code execution.

The first vulnerability, CVE-2026-109618, carries a CVSS v3.1 base score of 9.8 (CRITICAL). It occurs because PHP uses longjmp() for out-of-memory errors without properly initializing request memory in certain contexts. Subsequent cleanup routines may read or branch on uninitialized memory, leading to RCE. The second issue, CVE-2026-109619, scores 8.1 (HIGH) and involves global state that temporarily references request memory; failure to reset this state correctly can leave dangling pointers after memory is freed.

Affected products include RUGGEDCOM APE1808 running PAN-OS versions 10.2 All, 11.1 All, 11.2 All, 12.1 All, and 12.2 All. Both vulnerabilities are listed as known_affected. Siemens advises customers to upgrade to corresponding patched PAN-OS releases and contact support for additional remediation details.

Recommended Mitigations

  • Apply vendor fixes by upgrading to the latest available PAN-OS version.
  • Protect network access to devices using appropriate segmentation and firewalls.
  • Follow Siemens operational guidelines for Industrial Security.
  • Minimize internet exposure of control system devices and place them behind isolating firewalls.
  • Use VPNs for remote access while ensuring they remain updated.

The advisory was originally issued by Siemens ProductCERT and later republished by CISA as ICSA-26-316-05. It affects critical manufacturing sectors worldwide, with the vendor headquartered in Germany.

Meridian digestThe week's most consequential security stories, distilled into one briefing.See the digest

More in Vulns & Exploits

CISA Issues Advisory on Siemens Desigo CC and Gridscale Products Affected by Critical Brotli Vulnerability
Critical Flaws in Red Hat Quay Expose All Private Container Images to Read and Overwrite Attacks
SignDrop Zero-Day Exploit Abuses Windows CLFS Mitigation for SYSTEM Privileges